Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Front Pediatr ; 12: 1378008, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38633325

RESUMO

Introduction: Approximately 1.5 million neonatal deaths occur among premature and small (low birthweight or small-for gestational age) neonates annually, with a disproportionate amount of this mortality occurring in low- and middle-income countries (LMICs). Hypothermia, the inability of newborns to regulate their body temperature, is common among prematurely born and small babies, and often underlies high rates of mortality in this population. In high-resource settings, incubators and radiant warmers are the gold standard for hypothermia, but this equipment is often scarce in LMICs. Kangaroo Mother Care/Skin-to-skin care (KMC/STS) is an evidence-based intervention that has been targeted for scale-up among premature and small neonates. However, KMC/STS requires hours of daily contact between a neonate and an able adult caregiver, leaving little time for the caregiver to care for themselves. To address this, we created a novel self-warming biomedical device, NeoWarm, to augment KMC/STS. The present study aimed to validate the safety and efficacy of NeoWarm. Methods: Sixteen, 0-to-5-day-old piglets were used as an animal model due to similarities in their thermoregulatory capabilities, circulatory systems, and approximate skin composition to human neonates. The piglets were placed in an engineered cooling box to drop their core temperature below 36.5°C, the World Health Organizations definition of hypothermia for human neonates. The piglets were then warmed in NeoWarm (n = 6) or placed in the ambient 17.8°C ± 0.6°C lab environment (n = 5) as a control to assess the efficacy of NeoWarm in regulating their core body temperature. Results: All 6 piglets placed in NeoWarm recovered from hypothermia, while none of the 5 piglets in the ambient environment recovered. The piglets warmed in NeoWarm reached a significantly higher core body temperature (39.2°C ± 0.4°C, n = 6) than the piglets that were warmed in the ambient environment (37.9°C ± 0.4°C, n = 5) (p < 0.001). No piglet in the NeoWarm group suffered signs of burns or skin abrasions. Discussion: Our results in this pilot study indicate that NeoWarm can safely and effectively warm hypothermic piglets to a normal core body temperature and, with additional validation, shows promise for potential use among human premature and small neonates.

2.
Annu Rev Biomed Eng ; 25: 257-280, 2023 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-37068765

RESUMO

A shift in the traditional technocentric view of medical device design to a human-centered one is needed to bridge existing translational gaps and improve health equity. To ensure the successful and equitable adoption of health technology innovations, engineers must think beyond the device and the direct end user and must seek a more holistic understanding of broader stakeholder needs and the intended context of use early in a design process. The objectives of this review article are (a) to provide rationale for the need to incorporate meaningful stakeholder analysis and contextual investigation in health technology development and biomedical engineering pedagogy, (b) to review existing frameworks and human- and equity-centered approaches to stakeholder engagement and contextual investigation for improved adoption of innovative technologies, and (c) to present case studyexamples of medical device design that apply these approaches to bridge the gaps between biomedical engineers and the contexts for which they are designing.


Assuntos
Tecnologia Biomédica , Desenho de Equipamento , Humanos
3.
Anal Chem ; 87(15): 7872-9, 2015 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-26125635

RESUMO

The 2009 Influenza A (H1N1) pandemic disproportionately affected the developing world and highlighted the key inadequacies of traditional diagnostic methods that make them unsuitable for use in resource-limited settings, from expensive equipment and infrastructure requirements to unacceptably long turnaround times. While rapid immunoassay diagnostic tests were much less costly and more context-appropriate, they suffered from drastically low sensitivities and high false negative rates. An accurate, sensitive, and specific molecular diagnostic that is also rapid, low-cost, and independent of laboratory infrastructure is needed for effective point-of-care detection and epidemiological control in these developing regions. We developed a paper-based assay that allows for the extraction and purification of RNA directly from human clinical nasopharyngeal specimens through a poly(ether sulfone) paper matrix, H1N1-specific in situ isothermal amplification directly within the same paper matrix, and immediate visual detection on lateral flow strips. The complete sample-to-answer assay can be performed at the point-of-care in just 45 min, without the need for expensive equipment or laboratory infrastructure, and it has a clinically relevant viral load detection limit of 10(6) copies/mL, offering a 10-fold improvement over current rapid immunoassays.


Assuntos
Técnicas Genéticas , Vírus da Influenza A Subtipo H1N1/genética , Influenza Humana/diagnóstico , RNA/genética , Técnicas Genéticas/economia , Técnicas Genéticas/instrumentação , Técnicas Genéticas/normas , Humanos , Vírus da Influenza A Subtipo H1N1/química , Vírus da Influenza A Subtipo H1N1/isolamento & purificação , Limite de Detecção , Papel , Sistemas Automatizados de Assistência Junto ao Leito , RNA/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA